Blender Pump HST100
Blender Pump HST100: used for large-volume liquid supply during continuous fracturing, sand mixing operations; modular service-friendly layout
Product Overview
Blender Pump HST100 is presented using the supplied product text, model data, and service context.
HST100 blender pump is a high-flow supporting pump for blender and mixing system, mainly used for large-volume liquid supply during continuous fracturing and sand mixing operations.
It is positioned for large-volume liquid supply during continuous fracturing and sand mixing operations. The material highlights service access, installation flexibility, and stable long-run operation.
The specification rows also give a second check through Rated Power is listed as 90 kW and Pump Stage is listed as Single Stage.
Model Focus
- Series family: Blender Pump Series
- Model record: keep the page tied to the supplied table and series page.
- Configuration: confirm the installation envelope before release.
- Primary use: large-volume liquid supply during continuous fracturing
- Feature focus: service access
- Feature focus: installation flexibility
Key Structural Features
Blender Pump HST100 focuses on service access, installation flexibility, and stable long-run operation in the structural description.
The technical description highlights service access, installation flexibility, and stable long-run operation.
For Blender Pump HST100, service access helps shorten inspection time and keeps routine maintenance simpler. Blender Pump HST100 is described with installation flexibility in mind, which makes layout planning easier for the buyer. Blender Pump HST100 is tied to stable long-run operation, which supports uninterrupted field use.
The extracted feature list keeps Blender Pump HST100 grounded in High-efficiency centrifugal impeller, wear-resistant volute, and mechanical seal.
Reading the structure alongside Rated Power is listed as 90 kW and Pump Stage is listed as Single Stage keeps the page closer to the source file.
- High-efficiency centrifugal impeller
- wear-resistant volute
- mechanical seal
- modular skid structure
- easy integration with blender equipment.
What the layout emphasizes
- Theme focus: service access
- Theme focus: installation flexibility
- Theme focus: stable long-run operation
- Feature note: High-efficiency centrifugal impeller
- Feature note: wear-resistant volute
Application Areas
Blender Pump HST100 is positioned for large-volume liquid supply during continuous fracturing and sand mixing operations.
Blender Pump HST100 stays centered on large-volume liquid supply during continuous fracturing and sand mixing operations in the extracted application notes.
That scope matters because it keeps the page focused on the real duty point instead of turning Blender Pump HST100 into a generic pump description.
The application note can be checked against Rated Power = 90 kW and Pump Stage = Single Stage to keep the page grounded in the table.
Service focus
- Primary use: large-volume liquid supply during continuous fracturing
- Application note: sand mixing operations
Selection / Configuration Notes
Blender Pump HST100 should be matched to continuous feed, mixing stability, and skid fit.
Blender Pump HST100 is listed for large-volume liquid supply during continuous fracturing and sand mixing operations, so the final package should stay matched to that duty set.
The structure of Blender Pump HST100 highlights service access and installation flexibility, so the final selection should keep those conditions in view.
The specification rows for Blender Pump HST100 make the final package easier to validate through Rated Power = 90 kW and Pump Stage = Single Stage.
The model becomes easier to place when the selection notes are read against Rated Power is listed as 90 kW, Pump Stage is listed as Single Stage, and Structural Form is listed as Horizontal Centrifugal Pump.
Before ordering
- Confirm the duty point against the table and the skid path for Blender Pump HST100.
- Keep the skid fit, feed path, and mixing stability aligned.
- Verify the blending medium and layout path against the table.
- Primary use: large-volume liquid supply during continuous fracturing
- Rated Power: 90 kW
- Pump Stage: Single Stage
Practical Model Check
Blender Pump Series should be read together with the table and the duty point.
Send the model name, duty point, and installation constraints for Blender Pump HST100 so the fit check stays specific.
The family may stay close, but the final model should change if the skid layout is off.
Quick check
- Series family: Blender Pump Series
- Selection focus: continuous feed, mixing stability, and skid fit
- Use the parameter table before quotation and keep the skid path visible.
- Confirm the blend medium, duty cycle, and skid path.
Product Parameters
| Main Technical Specifications | |
|---|---|
| Rated Power | 90 kW |
| Pump Stage | Single Stage |
| Structural Form | Horizontal Centrifugal Pump |
| Applicable Medium | Clean Water, Fracturing Fluid, Low-sand Slurry |
Operating Parameters
| Parameter Item | Technical Data |
|---|---|
| Max Working Pressure | 1.6 MPa |
| Rated Displacement | 130 m³/h |
| Rated Rotating Speed | 2900 r/min |
| Operating Temperature Range | -20℃ ~ 80℃ |
| Continuous Operating Time | ≥72 h |
Inquiry Path
Reduce friction and keep the CTA visible.
Send the model name, duty point, and installation constraints for Blender Pump HST100 so the fit check stays specific.
Contact
PHONE:+86-13062870081
EMAIL:sales@sjpetroleummachinery.com
ADDRESS:Siji Road, Jingzhou District, Jingzhou City, Hubei Province, China
Related Models
Keep the comparison close to this model family.
Next Pages
Move from the exact Blender Pump Series model to the pages that support the buying decision.
Blender Pump Series
Go back to the blender family and compare sibling model tables.
Open seriesBlender Pump HST100 spare parts
Open the blender spare-parts path for skid-mounted service items.
Open spare partsSelection Guide
Use this guide when skid fit, feed rate, and mixing stability still need a final check.
Open guideFAQ
Use the quick answers when the inquiry needs a fast first pass on blender fit.
Open guide